Myron L Ultrameter II Oman – Reliable 7-Parameter 6PFCE Meter

ر.ع.585.00

Myron L Ultrameter II 6PFCE portable water quality meter for conductivity, resistivity, TDS, pH, ORP, free chlorine equivalent and temperature. USA-made, IP67 waterproof housing, 100-reading memory and automatic temperature compensation. Available from UV Water Systems, Muscat, Oman.

Category:

Description

Myron L Ultrameter II Oman is a portable water quality testing solution for technicians, laboratories and water treatment operators. The USA-made Ultrameter II 6PFCE combines conductivity, resistivity, total dissolved solids (TDS), pH, oxidation-reduction potential (ORP), free chlorine equivalent (FCE) and temperature in one handheld instrument. Request a quote from UV Water Systems in Muscat for the model and accessories required for your application.

Myron L Ultrameter II Oman: 7 measurement functions

The 6PFCE helps operators check several water quality parameters without carrying separate meters. Its built-in sample cells and four-digit LCD support convenient testing in the field or laboratory. Fill the appropriate cell with the sample, select the parameter and read the result. Automatic ranging simplifies measurements across different water sources.

  • Conductivity for monitoring ionic content and treatment performance.
  • Resistivity for checking low-conductivity water.
  • TDS for assessing dissolved-solids levels.
  • pH for checking acidity and alkalinity.
  • ORP for monitoring oxidation-reduction conditions.
  • FCE for an ORP- and pH-based free chlorine equivalent reading.
  • Temperature for recording sample conditions.

Technical specifications

Specification Ultrameter II 6PFCE
Conductivity range 0–9999 µS/cm; 10–200 mS/cm, five autoranges
TDS range 0–9999 ppm; 10–200 ppt, five autoranges
Resistivity range 10 kΩ–30 MΩ
pH range 0–14 pH
ORP range ±999 mV
FCE range 0.00–9.99 ppm, subject to the manufacturer’s specified pH and ORP conditions
Temperature measurement range 0–71°C
Conductivity / TDS / resistivity accuracy ±1% of reading
Memory 100 readings with date and time stamp
Power One 9V alkaline battery
Battery life More than 100 hours / approximately 5,000 readings
Protection IP67 / NEMA 6; waterproof to 1 metre and buoyant
Operating / storage temperature 0–55°C
Dimensions 196 × 68 × 64 mm
Weight 352 g

Reliable testing for water treatment applications

For reverse osmosis systems, conductivity and TDS readings help operators compare feed and treated water. Recording readings over time can support routine performance checks and maintenance planning. Resistivity measurement is useful when monitoring deionized water, while pH and ORP provide additional information for process monitoring.

Other applications include cooling towers, desalination, irrigation, hydroponics, wastewater and laboratory testing. Select the instrument according to the water chemistry, measurement range and procedures used at your site. A meter reading alone does not establish that water is safe to drink; use the appropriate testing programme for the application.

Practical features for field work

The Myron L Ultrameter II Oman listing includes a meter platform with a four-electrode conductivity cell, automatic temperature compensation and selectable KCl, NaCl and 442 natural water standards. Users can adjust temperature compensation and the conductivity-to-TDS conversion ratio to suit their testing requirements. The waterproof, floating housing is useful around tanks, plant rooms and sampling points.

Store up to 100 readings with date and time stamps to keep inspection records organised. Non-volatile memory retains stored data and calibration information when the battery is changed. Automatic shut-off helps conserve battery power. Wireless transfer is available with the optional bluDock accessory package; this accessory is not assumed to be included in the standard supply.

Calibration and model selection

Use suitable conductivity standards and pH buffers to maintain measurement accuracy. The 6PFCE includes calibration prompts and a field-replaceable pH/ORP sensor. Follow the manufacturer’s cleaning, storage and calibration instructions, particularly for the pH/ORP sensor. Ask for suitable calibration solutions, storage solution and protective cases when requesting your quotation.

The brochure also covers the Ultrameter II 4PII. That model measures conductivity, resistivity, TDS and temperature; it does not provide the 6PFCE model’s pH, ORP or FCE functions. Specify 6PFCE when all seven measurement functions are needed. FCE is derived from ORP and pH and should be used within the manufacturer’s stated conditions and application guidance.

Request a Myron L Ultrameter II Oman quotation

Contact UV Water Systems for a quotation for your Muscat or Oman project. Include the required model, quantity, water source, measurement parameters and any calibration certificate requirements. Availability, lead time, accessories and final supply scope will be confirmed in the quotation.

Browse our water treatment products in Oman and consult Myron L Company for manufacturer information. Request a quote for the Myron L Ultrameter II Oman with the accessories that match your testing routine.

Reviews

There are no reviews yet.

Be the first to review “Myron L Ultrameter II Oman – Reliable 7-Parameter 6PFCE Meter”

Your email address will not be published. Required fields are marked *