Electronic UV ballast, type PH2-800-2/75U, 800mA output driving two 75W high output germicidal lamps. For commercial and industrial UV reactors running Philips TUV 36T5 HO and equivalent HO tubes. Stocked in Muscat by UV Water Systems.

Description

UV ballast PH2-800-2/75U Oman — 800mA twin-lamp driver for 75W high output germicidal lamps

UV ballast PH2-800-2/75U Oman

The PH2-800-2/75U UV ballast is an 800mA electronic driver built to run two 75W high output germicidal lamps from a single unit, and UV Water Systems supplies it in Oman. High output lamps draw substantially more current than standard tubes, and this is the class of driver they need — a 425mA unit will light an HO lamp but will never bring it to rated 254 nm output.

Twin-lamp drivers are used on multi-lamp reactors to reduce the number of components in the enclosure, which is efficient until one output fails. When a single position on a twin driver goes dark and the other stays lit, the ballast is the fault, not the lamp. Keep a spare driver on site for any reactor where losing half the lamp bank takes the plant off specification.

UV ballast PH2-800-2/75U Oman — technical specifications

Type PH2-800-2/75U
Output current 800 mA
Lamp rating 2 × 75 W high output
Construction Electronic, potted
Function Strike and regulated current control for HO UV-C lamps
Mounting Panel or enclosure, plant room
Supplied by UV Water Systems — Uniqueness View LLC, Muscat, Oman

UV ballast PH2-800-2/75U Oman — lamp compatibility

  • Philips TUV 36T5 HO 75W G5 (two lamps)
  • Other 75W high output germicidal lamps at 800 mA
  • Twin-lamp positions in commercial and industrial UV reactors
  • Not suitable for 40W standard-output lamps

Do not fit standard-output 40W tubes on this driver. The higher current will run them hard, shorten life sharply and can crack the lamp seals. Confirm lamp wattage, lamp count and input voltage against the existing ballast label before ordering.

Where the UV ballast PH2-800-2/75U Oman is used

This driver class is fitted on commercial and industrial UV reactors in Oman — hotel and hospital building supply, food and beverage process water, oil and gas facility potable systems, effluent reuse and high-flow potable lines. UV Water Systems designs, supplies and maintains these systems and can provide UV intensity verification and component change records for the maintenance file.

Diagnosing a failed UV ballast PH2-800-2/75U Oman

A UV lamp that will not strike is not always a dead lamp. Before condemning the tube, check the ballast. The usual sequence is: confirm supply voltage at the ballast input, check the lamp pins and holder for corrosion or heat damage, then fit a known-good lamp. If a known-good lamp still will not strike, the ballast has failed. If the lamp strikes but the controller reports low UV intensity, the fault is more likely the lamp or a fouled quartz sleeve.

Ballasts fail more often in Oman than the manufacturer’s life figures suggest, and the reason is heat. A driver mounted in an unventilated plant room at 45 degrees ambient, or bolted to the sun-facing side of an outdoor enclosure, runs its electrolytic capacitors well beyond their design temperature. Mount ballasts in shade with airflow, keep them off hot pipework, and expect to replace them on a defined cycle rather than on failure at any site where the plant room is not cooled.

Standards and references

The UV dose a chamber must deliver, and the reasoning behind the annual lamp change, come from published drinking water guidance rather than from equipment marketing. The WHO Guidelines for Drinking-water Quality set out the microbiological targets disinfection is designed to meet, and the International Ultraviolet Association publishes the dose and validation practice the industry works to. We size and service UV systems in Oman against those references.

Buying a UV ballast PH2-800-2/75U Oman in Oman

UV Water Systems has supplied and serviced ultraviolet disinfection equipment across the Sultanate for more than 14 years, for hospitals, oil and gas sites, schools, hotels, food and beverage plants and villas. We keep UV ballasts and germicidal lamps in stock in Muscat, so a system that loses disinfection does not wait weeks for an air freight shipment.

Uniqueness View LLC is ISO 9001:2015 certified. Call +968 9763 7786 or email sales@waterfilteroman.com for stock, bulk pricing on service-contract quantities, or help matching a ballast to a lamp you cannot identify. Send a photo of the lamp, the old ballast label and the chamber nameplate and we will specify the correct unit. Our technicians cover Muscat, Sohar, Nizwa, Salalah and Duqm.

See also our UV sterilizer systems, UV lamps and spares and replacement quartz sleeves.

Additional information

Type

PH2-800-2/75U

Output Current

800 mA

Lamp Rating

75 W High Output

Lamps Driven

2

Construction

Electronic

Reviews

There are no reviews yet.

Be the first to review “Electronic UV Ballast PH2-800-2/75U – 800mA Twin-Lamp Driver for 75W High Output Lamps | UV Water Systems Oman”

Your email address will not be published. Required fields are marked *